导读: - at which point (”terminals”) - what is connected (e.g. pressure transmitter/type/ pressure range) 8 RS8EM102 Danfoss 02-2009 AK-CC 750 丹佛斯电子膨胀阀控制器AK-CC750 1. Controller TypeAK-CC 750 F

- at which point (”terminals”)

- what is connected (e.g. pressure transmitter/type/ pressure range)

8 RS8EM102 © Danfoss 02-2009

AK-CC 750

丹佛斯电子膨胀阀控制器AK-CC750

1. Controller

TypeAK-CC 750

Function

Controller for evaporator control

Application

Refrigeration appliances control

3. AK operation and accessories

TypeOperationAK-ST 500

--AccessoriesAK-PS 075AK-PS 150AccessoriesEKA 163BEKA 164B

-AccessoriesAK-OB 101A

Software for operation of AK controllersCable between PC and AK controller

Cable between zero modem cable and AK controller /Cable between PDA cable and AK controllerTransformer module 230 V / 115 V to 24 V18 VA, 24 V d.c.36 VA, 24 V d.c.

AK-operationAK - Com portAK - RS 232

Function

Application

Supply for controller

External display that can be connected to the controller module. For showing, say, the refrigeration appliancesDisplay

Display with operation buttonsCable between display and controller

Length = 2 mLength = 6 m

Real time clock for use in controllers that require a clock function, but are not wired with data communication.Real time clock with battery backup.

To be mounted in an AK controller

On the following pages there is data specific to each module.

AK-CC 750 RS8EM102 © Danfoss 02-2009

9

丹佛斯电子膨胀阀控制器AK-CC750

Common data for modules

Supply voltagePower consumption

24 V d.c. / a.c. +/- 20%AK-__ (controller)AK-XM 101, 102AK-XM 204, 205

Analog inputs

Pt 1000 ohm /0°C

Pressure transmitter type AKS 32R / AKS 2050 / AKS 32 (1-5 V)Voltage signal 0-10 VContact function (On/Off)

8 VA2 VA5 VA

Resolution: 0.1°C

Accuracy: +/- 0.5°C (between -50°C and +50°C)

Resolution:1 mV Accuracy +/- 10 mV

Max. connection of 5 pressure transmitters on one moduleOn at R < 20 ohmOff at R > 2K ohm

(Gold -plated contacts not necessary)Off: U < 2 V On: U > 10 VOff: U < 24 V On: U > 80 V4 A3 A

Min. 24 VMax. 230 V

Low and high voltage must not be connected to the same output group

Max. 240 V a.c. , Min. 48 V a.c.Max. 0.5 A, Leak < 1 mAMax. 1 AKV-40 to 70°C

-20 to 55°C ,

0 to 95% RH (non condensing) No shock influences / vibrationsPC / ABSIP10 , VBG 4

For mounting on panel wall or DIN railCa. 200 g / 500 g / 600 g

LVD tested according to EN 60730EMC tested

Immunity according to EN 61000-6-2Emission according to EN 61000-6-3UL file number: E166834

On/off supply voltage inputs

Low voltage0 / 80 V a.c./d.c.High voltage0 / 260 V a.c.

Relay outputs SPDT

AC-1 (ohmic)AC-15 (inductive)U

Solid state outputs

Can be used for loads that are cut in and out frequently, e.g. :

rail heat, fans and AKV valveDuring transportDuring operation

Ambient temperature

EnclosureMaterialDensityMounting

Weight with screw terminalsApprovals

modules in100- / 200- / controller-seriesEU low voltage directive and EMC require-ments are complied with

UL 873,

The mentioned data applies to all modules.

If data is specific, this is mentioned together with the module in question.

10 RS8EM102 © Danfoss 02-2009

AK-CC 750

丹佛斯电子膨胀阀控制器AK-CC750

Dimensions

The module dimension is 72 mm.

Controllers consist of three modules

The length of an aggregate unit = n x 72 + 8

AK-CC 750 RS8EM102 © Danfoss 02-2009 11

丹佛斯电子膨胀阀控制器AK-CC750

Controller

Function

There are several controllers in the series. The function is deter-mined by the programmed software, but outwardly the control-lers are identical – they all have the same connection possibilities:11 analog inputs for sensors, pressure transmitters, voltage signals and contact signals.

8 digital outputs, with 4 Solid state outputs and 4 relay outputsSupply voltage

24 V a.c. or d.c. to be connected to the controller.

The 24 V must not be retransmitted and used by other control-lers as it is not galvanically separated from inputs and outputs. In other words, you must use a transformer for each controller. Class II is required. The terminals must not be earthed.

The supply voltage to any extension modules is transmitted via the plug on the right-hand side.

The size of the transformer is determined by the power require-ment of the total number of modules.

The supply voltage to a pressure transmitter can be taken either from the 5 V output or from the 12 V output depending on trans-mitter type.

Data communication

If the controller is to be included in a system, communica-tion must take place via the LON connection.

The installation has to be made as mentioned in the sepa-rate instructions for LON communication.Address setting

When the controller is connected to a gateway type AKA 245, the controller’s address must be set between 1 and 119. (1-200 at AK-SM..).

Service PIN

When the controller is connected to the data communication ca-ble the gateway must have knowledge of the new controller. This is obtained by pushing the key PIN. The LED “Status” will flash fast when the gateway sends an acceptance message.

Operation

The configuration operation of the controller must take place from the software programme “Service Tool”. The program must be installed on a PC, and the PC must be connected to the controller via the network plug on the front of the unit.

Light-emitting diodes

There are two rows with LED’s. They mean:Left row:

Voltage sup …… 此处隐藏:4827字,全部文档内容请下载后查看。喜欢就下载吧 ……

丹佛斯电子膨胀阀控制器AK-CC750(3).doc 将本文的Word文档下载到电脑,方便复制、编辑、收藏和打印
本文链接:https://www.jiaowen.net/wenku/105946.html(转载请注明文章来源)
Copyright © 2020-2025 教文网 版权所有
声明 :本网站尊重并保护知识产权,根据《信息网络传播权保护条例》,如果我们转载的作品侵犯了您的权利,请在一个月内通知我们,我们会及时删除。
客服QQ:78024566 邮箱:78024566@qq.com
苏ICP备19068818号-2
Top
× 游客快捷下载通道(下载后可以自由复制和排版)
VIP包月下载
特价:29 元/月 原价:99元
低至 0.3 元/份 每月下载150
全站内容免费自由复制
VIP包月下载
特价:29 元/月 原价:99元
低至 0.3 元/份 每月下载150
全站内容免费自由复制
注:下载文档有可能出现无法下载或内容有问题,请联系客服协助您处理。
× 常见问题(客服时间:周一到周五 9:30-18:00)