SepTor 2038 Project-09066

操作手册

Rev. 1 June 9th 2010

目录

1. 启动系统..................................................................................................1 2. 主控制画面..............................................................................................2 3. 操作接口..................................................................................................3

3.1. 操作模式............................................................................................................4

3.1.1. Septor操作模式..................................................................................................4 3.1.2. 控制端.................................................................................................................5

3.1.2.1. 操作与控制................................................................................................6 3.1.3. 液压单元控制......................................................................................................7 3.1.4. 授权管理.............................................................................................................8

4. 操作画面................................................................................................10

4.1. 液压控制屏幕...................................................................................................10

4.1.1. 液压单元...........................................................................................................11 4.1.2. 液压系统油位....................................................................................................12 4.1.3. 液压油的过滤....................................................................................................12

4.2. 转盘控制屏幕...................................................................................................12

4.2.1. 转盘显示...........................................................................................................15 4.2.2. 时间控制...........................................................................................................15

4.3. 报警屏幕..........................................................................................................16 4.4. 趋势屏幕..........................................................................................................17

5. 服务画面................................................................................................20

5.1. 设置画面..........................................................................................................20

5.1.1.2. 液压单元服务功能....................................................................................21 5.1.1.3. 调整液压单元压力....................................................................................22

5.2. PLC输入输出状态屏幕....................................................................................23 5.3. PLC 屏幕.........................................................................................................24

6. 超级用户控制屏幕.................................................................................25

6.1. 常数参数屏幕...................................................................................................25

6.1.1. 复位旋转阀位置................................................................................................26

6.2. 强制状态控制屏幕(仅供制造商服务用)........................................................27

7. 维护保养................................................................................................28 8. SEPTOR 停机的处理方法.....................................................................29 9. 紧急停止................................................................................................30

操作手册

Rev. 1 June 9th 2010

1. 启动系统

启动系统步骤: 1. 2. 3.

合上控制柜面板上的主电源开关。

等待触摸屏上的控制画面引导启动,并显示出控制画面。 复位及准备启动系统.

复位按钮位于控制柜面板上“SYSTEM RESET”.

如果急停按钮被按下,还需要将其复位,控制柜上的急停按钮通过向外拉来复位,控制现场按钮盒上的急停按钮通过顺时针旋转来复位。 按下控制柜面板上的复位按钮,此时液压系统将被运行启动。 第2次按下控制面板上的复位按钮,系统伺服通电准备运行。

4.

正常情况下控制柜上的报警灯应处于熄灭状态,如果不是这样,则表明系统存在报警信息,具体情况请参考章节4.3

操作手册

Rev. 1 June 9th 2010

2. 主控制画面

SepTor 的控制界面是位于控制柜上的触摸屏。

Figure 1

主控制画面

1. 2.

触摸屏上包含有控制操作按钮。

通过不同的功能按钮,用于可以实现不同的控制操作。

用户只能操作具有黄色背景的输入参数,灰色背景内的数据是无法操作的。 按下黄色背景框内的数据,在触摸屏上将出现一个数字键盘。 通过数字键盘输入需要的数据,并按“ Enter”键确认输入。

要返回主操作屏幕按左下角“Main”按钮。

操作手册

Rev. 1 June 9th 2010

3. 操作接口

操作接口包含下列几个部分; 1.

控制模式设置

Septor 状态: Auto(自动)/Manual(手动) 2.

液压系统状态: On(开)/Off(关)

控制端状态: Remote(远端;未使用)/Local(本地)

授权等级: Operator(操作模式)/Service(服务模式)/Super User

(超级用户)。

液压系统压力

PM: 主压力

操作手册

Rev. 1 June 9th 2010

PCA: 回路A压力 PCB: 回路B压力 3.

运行时间 4. 5. 6. 7.

Total Operation - 系统运行累计时间

操作屏幕;参考章节 4. 服务屏幕;参考章节 5. 超级用户屏幕;参考章节 6. 运行时间 =

N x (等待时间) + N x (移动时间) N= 阀芯孔位数

3.1. 操作模式

3.1.1. Septor操作模式

Figure 3

操作模式

Septor系统包含如下操作模式; Manual(手动)

操作手册

Rev. 1 June 9th 2010 …… 此处隐藏:3979字,全部文档内容请下载后查看。喜欢就下载吧 ……

(西门子离交设备使用说明书)06 Operating_NoEncoder中文.doc 将本文的Word文档下载到电脑,方便复制、编辑、收藏和打印
本文链接:https://www.jiaowen.net/wenku/124738.html(转载请注明文章来源)
Copyright © 2020-2025 教文网 版权所有
声明 :本网站尊重并保护知识产权,根据《信息网络传播权保护条例》,如果我们转载的作品侵犯了您的权利,请在一个月内通知我们,我们会及时删除。
客服QQ:78024566 邮箱:78024566@qq.com
苏ICP备19068818号-2
Top
× 游客快捷下载通道(下载后可以自由复制和排版)
VIP包月下载
特价:29 元/月 原价:99元
低至 0.3 元/份 每月下载150
全站内容免费自由复制
VIP包月下载
特价:29 元/月 原价:99元
低至 0.3 元/份 每月下载150
全站内容免费自由复制
注:下载文档有可能出现无法下载或内容有问题,请联系客服协助您处理。
× 常见问题(客服时间:周一到周五 9:30-18:00)